agilent
-
پمپ خلاء خشک | پمپ خلا MSD Dry Pump
Agilent Chromatograph MSD Dry Pump
- Integral Leak Rate: 1 mbar l/sec
- Number of Cylinders: 4
- Nominal Volume Flow Rate: 3.0 m3/h (50 Hz)
- Permissible Exhaust Pressure: 1100 mbar
- Remanufactured Agilent G3170-80028 MVP 055-3 Diaphragm Dry Vacuum Pump, 100-120 V, 200-240 V 50/60 Hz, PKT01301 gas chromatography / mass spectrometry foreline pump for use with series 5975
-
پمپ خلاء | پمپ خلا آزمایشگاهی | قیمت پمپ خلا
DS 602 Varian :
*Dual Stage Rotary Vane Vacuum Pump
*Applications:
Analytical Instruments
Mass Spectrometry
Electron Microscopes
Leak Detection
Industrial Vacuum Processes
High Energy Physics
Reasearch Laboratories
*Free air displacement: 504 l/min
*Pumping speed: 25 m3/h
*Ultimate partial pressure: 10-4 mbar
*Ultimate total pressure: 2 x 10-3 mbar
*Ultimate total pressure with gas ballast: 1 x 10-2 mbar
*Water vapor tolerance: 30 mbar
*Water vapor capacity: 550 g/h
*Oil capacity min/max: 0.5/1 l
*Motor rating 1ph: 0.75 kW
*Nominal rotation speed: 1500 rpm
*Weight: 35Kg
*Inlet flange: 25KF DN
*Exhaust flange: 25KF DN
-
اسپکتروفلوریمتر | خرید اسپکتروفلوریمتر | فروش اسپکتروفلوریمتر
Cary Eclipse Fluorescence Spectrophotometer
*Modes for : fluorescence,phosphorescence and
bio-/chemi-luminescence
*Dimensions(WxDxH) : 60 x 64 x 27 cm (23 x 25 x 10 inches)
*QuantityEa Sensitivity: > 500:1 RMS, 500 nm excitation, excitation and emission slits 10 nm / > 750:1 RMS, 350 nm excitation, excitation and emission slits 10 nm
*Wavelength(s): 190 – 1100 nm
*Temperature Range: 10 – 35°C
*Optical SystemCerny-Turner 0.125 m Monochromators
*Light Source: Xenon Flash Lamp
-
اتوسمپلر آجیلنت SPS4
*high-capacity (up to 360 samples or 768 microtiter wells)
*Dimensions: Width 600 mm Depth 320 mm Depth 363 mm including peristaltic pump Height 510 mm
*Weight: 15 kg
*Rinse port flow rate: Programmable, up to 50 mL/min depending on pump tube diameter
*Communication: USB 2.0 (full speed) virtual com port with plug-and-play capability.
*AUX interface: RS485 for future upgradability to external device control.
-
اتوسمپلر آجیلنت ۷۶۹۳A
Syringe size: 1 to 500 µL
Solvent saving: 10%, 20%, 30%, 40%, 80% of syringe size (µL)
Injection volume: 1 – 50% of syringe size (µL)
Sample pumps: 0 – 15
Viscosity delay: 0 – 7 seconds
-
اتوسمپلر ASX 520
ASX 520
Operating Temperature: 10° to 30°C
Relative Humidity: 0% to 95%
Altitude: 0 to 10000 Ft
Dimensions (H x W x D): 61 with sample probe x 48.2 x 48.2 cmWeight: 10.5 kg
Trays: 4 racks capacity
Communication interface: USB (virtual COM port); 2 Serial (RS-232) ports
Power supply: 100-240 VAC, 47-63 Hz, 1.9A