agilent
-
قیمت پمپ خلا | پمپ خلا آزمایشگاهی Agilent
MS40+ Mono Stage Rotary Vane Pump:
*MS40+ RVP, 25KF Inlet Flange, with I/O and RS232/485 Interface, without Oil Level Sensor
*Free air displacement: 828 l/min (29.2 cfm; 49.7 m 3 /h)
*Pumping Speed: (at 5 mbar inlet pressure) 40 m 3 /h
*Ultimate Total Pressure: 5×10 -2 mbar
*Oil Capacity min/max: 1 l
*Motor Rating 3ph: 0.75 kW
*Noise Level with gas ballast closed: ≤ 62 dB(A)
*Oil Temperature: 60 °C
*Pump operating: 140 °F
*IP Value: 20
*Installation category: II
*Pollution degree: 2
*Operating Temperature Range: 12 – 40 °C
*Nominal rotation speed: 1450 rpm
*Weight: 33 Kg
*Inlet Flange 949-9225: DN 25KF
*Inlet Flange 949-9240 / 949-9941: DN 40KF
*Exhaust Flange: DN 25KF
*Dimensions: 418 x 297 x 228 mm
*Nominal Input Voltage: 200-240 V
*Input frequency : 50 / 60 Hz
*Max input power: 1200 VA
*Internal Main Fuse: (TT type) 12.5 A
-
-
پمپ خلاء خشک | پمپ خلا MSD Dry Pump
Agilent Chromatograph MSD Dry Pump
- Integral Leak Rate: 1 mbar l/sec
- Number of Cylinders: 4
- Nominal Volume Flow Rate: 3.0 m3/h (50 Hz)
- Permissible Exhaust Pressure: 1100 mbar
- Remanufactured Agilent G3170-80028 MVP 055-3 Diaphragm Dry Vacuum Pump, 100-120 V, 200-240 V 50/60 Hz, PKT01301 gas chromatography / mass spectrometry foreline pump for use with series 5975
-
پمپ خلاء | پمپ خلا آزمایشگاهی | قیمت پمپ خلا
DS 602 Varian :
*Dual Stage Rotary Vane Vacuum Pump
*Applications:
Analytical Instruments
Mass Spectrometry
Electron Microscopes
Leak Detection
Industrial Vacuum Processes
High Energy Physics
Reasearch Laboratories
*Free air displacement: 504 l/min
*Pumping speed: 25 m3/h
*Ultimate partial pressure: 10-4 mbar
*Ultimate total pressure: 2 x 10-3 mbar
*Ultimate total pressure with gas ballast: 1 x 10-2 mbar
*Water vapor tolerance: 30 mbar
*Water vapor capacity: 550 g/h
*Oil capacity min/max: 0.5/1 l
*Motor rating 1ph: 0.75 kW
*Nominal rotation speed: 1500 rpm
*Weight: 35Kg
*Inlet flange: 25KF DN
*Exhaust flange: 25KF DN
-
-
پمپ خلاء خشک | پمپ خلا آزمایشگاهی
TriScroll-800 Dry Vacuum Pump:
*Pumping speed @ 60 Hz: 760 l/m, 48 m3 /hr, 28.3 cfm (at 60 Hz drive frequency, variable)
*Ultimate pressure: <1.3 x 10-1 mbar (1.0 x 10-1 Torr)
*Maximum inlet pressure: 1.0 atmosphere (0 psig) transient, 100 Torr steady state
*Maximum outlet pressure: 1.1 atmosphere (1.5 psig)
*Inlet connection: NW40
*Exhaust connection: 3 ⁄ 8 ” Female NPT with swivel (NW25 adapter provided)
*Exhaust connection adapter: NW 25 KF adapter provided
*Gas ballast: 1 ⁄ 4 ” Female NPT (shipped with port plug installed)
*Operating voltages: 200-240V, 1Ø, 50/60Hz
*Maximum line current: 200V; 6 A 240V; 5 A
*Weight – pump only: 32 kg (71 lbs)
*Compliance: CE, CSA/CUS
-
-
-
خرید کروماتوگراف مایع / فروش کروماتوگراف مایع Agilent
1260Infinity II
- Compatible with conventional and ultrahigh performance LC – with an operating pressure of up to 600 bar, the 1260 Infinity II Quaternary Pump and the 1260 Infinity Binary Pump are a perfect match for our Poroshell 120 columns.
- Analytical and semi-preparative purifications – the wide flow range of the 1260 Infinity II Quaternary Pump (up to 10 mL/min) perfectly supports standard and semi-preparative applications.
- Fast and precise gradients – the 1260 Infinity II Binary Pump is the perfect choice for fast and precise gradients using LC/MS, as well as UV-only systems.
- Ultralow carryover – the multiwash capability of the 1260 Infinity II Multisampler cleans all relevant injection parts between runs. This sophisticated, integrated feature flushes the injection needle outside with three solvents, and uses seat backflush procedures to reduce carryover to less than 10 ppm.
- Reduced cycle times – with Agilent’s unique dual-needle design, which allows you to run samples alternately through one or the other injection path. Cycle times can be reduced to mere seconds, virtually eliminating conventional wait times – whether for large volume loadings or flushing procedures.
- Efficient sample handling and logistics – using shallow well-plate drawers, the 1260 Infinity II Multisampler takes a maximum load of 16 microtiter plates and up to 6,144 samples – the most of any single system.
- Efficient column handling and temperature control – the 1260 Infinity II Multicolumn Thermostat holds up to four columns with direct access to each column through a Quick-Change switching valve, delivering flexibility and eliminating the need to disconnect and reconnect columns.
- Fast and easy connections – with InfinityLab Quick-Connect fittings to save time and trouble.
- Higher quality data – the 1260 Infinity II Diode Array Detector HS delivers lower detection limits and higher data quality for more confidence.
- Efficient control, acquisition and reporting – Agilent’s Instrument Control Framework (ICF) enables smooth control of Agilent LC instrumentation through third-party chromatography data systems.
-
فروش دستگاه جذب اتمی AA240 کمپانی agilent
فروش دستگاه جذب اتمی AA240 کمپانی
فروش جذب اتمی / خرید جذب اتمی / جذب اتمی چیست / طیف سنجی جذب اتمی / بدانیم در مورد atomic absorption / قیمت دستگاه جذب اتمی
اسپکتروفتومتری جذب اتمی (AAS)
طیف سنج جذب اتمی(AAS) Atomic Absorption Spectrometer یک روش طیف سنجی برای اندازه گیری مقدار عناصر شیمایی ، حاصل از جذب نور اتم در حالت گازی است .برای اندازه گیری مقدار یک عنصر در نمونه کار برد دارد. مبنای این روش جذب تشعشات الکترومغناطیس اتم های یک عنصر است . از این روش در شناسایی بیش از 70 عنصر استفاده می شود اما دقت در عناصر مختلف متفاوت می باشد
agilent
-
-
خرید Infinity II LC 1220 / فروش Infinity II LC 1220
Infinity II LC 1220
Weight 30 kg Dimensions 640 × 370 × 420 mm Permitted Ambient Temperature 4 ˚C – 55 ˚C Permitted Ambient Humidity < 95 % r.h. at 40 ˚C Hydraulic System Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and passive inlet valve Gradient Formation Low pressure dual mixing/gradient capability using proprietary high-speed proportioning valve, Pump delay volume 600 – 900 μl, system delay volume 800 – 1100 μl, dependent on back pressure Pressure Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 mL/min (all versions), Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 mL/min, Operating range 0 – 60 MPa (0 – 600 bar, 0 – 8700 psi) up to 5 mL/min Power Requirement 240 VA Flow Rate 0.2 – 10.0 mL/min Flow Precision <0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow Accuracy ± 1% or 10 μl/min whatever is greater Settable flow range 0.001 – 10 mL/min, in 0.001 mL/ min increments pH Range 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Injection Range 0.1 – 100 μL in 0.1 μL increments, Up to 1500 μL with multiple draw (hardware modification required) Replicate Injections 1 – 99 from one vial Sample Tray Capacity 100 × 2-mL vials in 1 tray, 15 × 6-mL vials in ½ tray (Agilent vials only), 40 × 2-mL vials in ½ tray Minimum Sample Volume 1 μL from 5 μL sample in 100 μL microvial, or 1 μL from 10 μL sample in 300 μL microvial Sample Viscosity Range 0.2 – 50 cp Injection Cycle Time Typically 50 s depending on draw speed and injection volume Column Oven Capacity (Internal volume: 6 μL), One 25-cm column Oven Temperature Range 5 °C above ambient to 80 °C Detector [Diode Array Detector (type: 1024-element diode array, Light source: Deuterium and tungsten, Sampling rate: 80 Hz, Wavelength range: 190-950 nm,, Slit width: 1,2,4,8,16 nm, Diode width: <1 nm)], [Variable Wavelength Detector (Detection type: Double-beam photometer, Light source: Deuterium lamp, Wavelength range: 190 – 600 nm, Band width: 6.5 nm typical)] Software ChemStation, EZChrom, Instrument Utility, LabAdvisor -
-
-
خرید کوره جذب اتمی / فروش کوره اجیلنت
GTA120 agilent
GTA 120 Zeeman:
*Extremely fast atomization
*Best signal-to-noise
*Reduced running costs
*Programmable Sample Dispenser (PSD)
*Simple method development
*Longer unattended runs
*Weight:
Net: 48 kg Shipping: 83 kg
*Dimensions (W x D x H):
Control unit 240 x 570 x 580 mm
Zeeman 220 x 290 x 340 mm
Packed 950 x 760 x 900 mm [includes PSD]
*Gas supplies:
Recommended pressure: 140 kPa (20 psi)
Maximum pressure: 350 kPa (50 psi)
Normal flow rate approx: 0–3.5 L/min
*Water Supply
Maximum temperature 40 °C (104 °F)
Recommended temp. range: 18–25 °C (64–70 °F)
Minimum flow rate required: 1.5 L/min at 180 kPa (27 psi)
Typical flow rate at recommended pressure range: 1.5–2.0 L/min
Maximum pressure to the regulator: 700 kPa (100 psi)
-
-
اتوسمپلر ASX 520
ASX 520
Operating Temperature: 10° to 30°C
Relative Humidity: 0% to 95%
Altitude: 0 to 10000 Ft
Dimensions (H x W x D): 61 with sample probe x 48.2 x 48.2 cmWeight: 10.5 kg
Trays: 4 racks capacity
Communication interface: USB (virtual COM port); 2 Serial (RS-232) ports
Power supply: 100-240 VAC, 47-63 Hz, 1.9A
-
-
نشر اتمی پلاسمای مایکروویو
MP4210-AES
*Wavelength Range: 213.857 to 614.171 nm (depending on element)
*Detection Limit: 1 to 6 ug/L
*Signal stability: < 2% RSD over 4 hours without internal standardization
or any form of drift correction.
*Resolution: < 0.050 nm (measured as full width at half maximum)
*Detection limits: 3 sigma detection limits (Μg/L) using a 10 second
integration time with dewar nitrogen.
*Applications: Geochemistry, Food Testing and Agriculture, Energy and Fuels, Environmental
*Dimensions: 66 x 66 x 90 cm
*Weight: 73 kg
-
اتوسمپلر آجیلنت ۷۶۹۳A
Syringe size: 1 to 500 µL
Solvent saving: 10%, 20%, 30%, 40%, 80% of syringe size (µL)
Injection volume: 1 – 50% of syringe size (µL)
Sample pumps: 0 – 15
Viscosity delay: 0 – 7 seconds
-
-
اسپکتروفلوریمتر | خرید اسپکتروفلوریمتر | فروش اسپکتروفلوریمتر
Cary Eclipse Fluorescence Spectrophotometer
*Modes for : fluorescence,phosphorescence and
bio-/chemi-luminescence
*Dimensions(WxDxH) : 60 x 64 x 27 cm (23 x 25 x 10 inches)
*QuantityEa Sensitivity: > 500:1 RMS, 500 nm excitation, excitation and emission slits 10 nm / > 750:1 RMS, 350 nm excitation, excitation and emission slits 10 nm
*Wavelength(s): 190 – 1100 nm
*Temperature Range: 10 – 35°C
*Optical SystemCerny-Turner 0.125 m Monochromators
*Light Source: Xenon Flash Lamp
-
اتوسمپلر آجیلنت SPS4
*high-capacity (up to 360 samples or 768 microtiter wells)
*Dimensions: Width 600 mm Depth 320 mm Depth 363 mm including peristaltic pump Height 510 mm
*Weight: 15 kg
*Rinse port flow rate: Programmable, up to 50 mL/min depending on pump tube diameter
*Communication: USB 2.0 (full speed) virtual com port with plug-and-play capability.
*AUX interface: RS485 for future upgradability to external device control.
-