دستگاه تیتراسیون کارل فیشر Aquamax KF
Measuring range: 1µg – 10 mg water
Moisture range: 1 ppm – 100 % water
Max. sensitivity: 0 . 1µg
Max. titration speed: 2 mg per minute
Max. electrolysis current: 400 ma
-
اسپکتروفتومتر PERKIN ELMER RX I (RX-1) FT-IR
FT-IR Spectrometer
Perkin Elmer
Spectrum RX1
Range: 450-4000 cm-1;
Resolution: 1 cm-1
IR Spectra of liquid/solid samples. -
اتوسمپلر آجیلنت SPS4
*high-capacity (up to 360 samples or 768 microtiter wells)
*Dimensions: Width 600 mm Depth 320 mm Depth 363 mm including peristaltic pump Height 510 mm
*Weight: 15 kg
*Rinse port flow rate: Programmable, up to 50 mL/min depending on pump tube diameter
*Communication: USB 2.0 (full speed) virtual com port with plug-and-play capability.
*AUX interface: RS485 for future upgradability to external device control.
-
اتوسمپلر آجیلنت ۷۶۹۳A
Syringe size: 1 to 500 µL
Solvent saving: 10%, 20%, 30%, 40%, 80% of syringe size (µL)
Injection volume: 1 – 50% of syringe size (µL)
Sample pumps: 0 – 15
Viscosity delay: 0 – 7 seconds
-
اتوسمپلر ASX 520
ASX 520
Operating Temperature: 10° to 30°C
Relative Humidity: 0% to 95%
Altitude: 0 to 10000 Ft
Dimensions (H x W x D): 61 with sample probe x 48.2 x 48.2 cmWeight: 10.5 kg
Trays: 4 racks capacity
Communication interface: USB (virtual COM port); 2 Serial (RS-232) ports
Power supply: 100-240 VAC, 47-63 Hz, 1.9A
-
خرید کوره جذب اتمی / فروش کوره اجیلنت
GTA120 agilent
GTA 120 Zeeman:
*Extremely fast atomization
*Best signal-to-noise
*Reduced running costs
*Programmable Sample Dispenser (PSD)
*Simple method development
*Longer unattended runs
*Weight:
Net: 48 kg Shipping: 83 kg
*Dimensions (W x D x H):
Control unit 240 x 570 x 580 mm
Zeeman 220 x 290 x 340 mm
Packed 950 x 760 x 900 mm [includes PSD]
*Gas supplies:
Recommended pressure: 140 kPa (20 psi)
Maximum pressure: 350 kPa (50 psi)
Normal flow rate approx: 0–3.5 L/min
*Water Supply
Maximum temperature 40 °C (104 °F)
Recommended temp. range: 18–25 °C (64–70 °F)
Minimum flow rate required: 1.5 L/min at 180 kPa (27 psi)
Typical flow rate at recommended pressure range: 1.5–2.0 L/min
Maximum pressure to the regulator: 700 kPa (100 psi)
-
خرید Mini Thermal Disorber/ فروش Mini Thermal Disorber
380,000,000 ریال7667A Mini Thermal Desorber
*Operating temp range: 5 to 45 °C
*Operating humidity range: 5 to 95% (noncondensing )
*Carrier gas: 50 -85 Psi
*Conditioning flow: 50 ml/min
*Conditioning time: 20 min
*Conditioning temperature: 320 °C
*Transfer line temperature: 150 °C
*Valve box temperature: 150 °C
*Type of carrier gas: Nitrogen/Helium
-
خرید Infinity II LC 1220 / فروش Infinity II LC 1220
Infinity II LC 1220
Weight 30 kg Dimensions 640 × 370 × 420 mm Permitted Ambient Temperature 4 ˚C – 55 ˚C Permitted Ambient Humidity < 95 % r.h. at 40 ˚C Hydraulic System Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and passive inlet valve Gradient Formation Low pressure dual mixing/gradient capability using proprietary high-speed proportioning valve, Pump delay volume 600 – 900 μl, system delay volume 800 – 1100 μl, dependent on back pressure Pressure Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 mL/min (all versions), Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 mL/min, Operating range 0 – 60 MPa (0 – 600 bar, 0 – 8700 psi) up to 5 mL/min Power Requirement 240 VA Flow Rate 0.2 – 10.0 mL/min Flow Precision <0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow Accuracy ± 1% or 10 μl/min whatever is greater Settable flow range 0.001 – 10 mL/min, in 0.001 mL/ min increments pH Range 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Injection Range 0.1 – 100 μL in 0.1 μL increments, Up to 1500 μL with multiple draw (hardware modification required) Replicate Injections 1 – 99 from one vial Sample Tray Capacity 100 × 2-mL vials in 1 tray, 15 × 6-mL vials in ½ tray (Agilent vials only), 40 × 2-mL vials in ½ tray Minimum Sample Volume 1 μL from 5 μL sample in 100 μL microvial, or 1 μL from 10 μL sample in 300 μL microvial Sample Viscosity Range 0.2 – 50 cp Injection Cycle Time Typically 50 s depending on draw speed and injection volume Column Oven Capacity (Internal volume: 6 μL), One 25-cm column Oven Temperature Range 5 °C above ambient to 80 °C Detector [Diode Array Detector (type: 1024-element diode array, Light source: Deuterium and tungsten, Sampling rate: 80 Hz, Wavelength range: 190-950 nm,, Slit width: 1,2,4,8,16 nm, Diode width: <1 nm)], [Variable Wavelength Detector (Detection type: Double-beam photometer, Light source: Deuterium lamp, Wavelength range: 190 – 600 nm, Band width: 6.5 nm typical)] Software ChemStation, EZChrom, Instrument Utility, LabAdvisor