خرید کروماتوگراف مایع / فروش کروماتوگراف مایع Agilent
1260Infinity II
- Compatible with conventional and ultrahigh performance LC – with an operating pressure of up to 600 bar, the 1260 Infinity II Quaternary Pump and the 1260 Infinity Binary Pump are a perfect match for our Poroshell 120 columns.
- Analytical and semi-preparative purifications – the wide flow range of the 1260 Infinity II Quaternary Pump (up to 10 mL/min) perfectly supports standard and semi-preparative applications.
- Fast and precise gradients – the 1260 Infinity II Binary Pump is the perfect choice for fast and precise gradients using LC/MS, as well as UV-only systems.
- Ultralow carryover – the multiwash capability of the 1260 Infinity II Multisampler cleans all relevant injection parts between runs. This sophisticated, integrated feature flushes the injection needle outside with three solvents, and uses seat backflush procedures to reduce carryover to less than 10 ppm.
- Reduced cycle times – with Agilent’s unique dual-needle design, which allows you to run samples alternately through one or the other injection path. Cycle times can be reduced to mere seconds, virtually eliminating conventional wait times – whether for large volume loadings or flushing procedures.
- Efficient sample handling and logistics – using shallow well-plate drawers, the 1260 Infinity II Multisampler takes a maximum load of 16 microtiter plates and up to 6,144 samples – the most of any single system.
- Efficient column handling and temperature control – the 1260 Infinity II Multicolumn Thermostat holds up to four columns with direct access to each column through a Quick-Change switching valve, delivering flexibility and eliminating the need to disconnect and reconnect columns.
- Fast and easy connections – with InfinityLab Quick-Connect fittings to save time and trouble.
- Higher quality data – the 1260 Infinity II Diode Array Detector HS delivers lower detection limits and higher data quality for more confidence.
- Efficient control, acquisition and reporting – Agilent’s Instrument Control Framework (ICF) enables smooth control of Agilent LC instrumentation through third-party chromatography data systems.
-
پمپ خلاء خشک | پمپ خلا آزمایشگاهی
TriScroll-800 Dry Vacuum Pump:
*Pumping speed @ 60 Hz: 760 l/m, 48 m3 /hr, 28.3 cfm (at 60 Hz drive frequency, variable)
*Ultimate pressure: <1.3 x 10-1 mbar (1.0 x 10-1 Torr)
*Maximum inlet pressure: 1.0 atmosphere (0 psig) transient, 100 Torr steady state
*Maximum outlet pressure: 1.1 atmosphere (1.5 psig)
*Inlet connection: NW40
*Exhaust connection: 3 ⁄ 8 ” Female NPT with swivel (NW25 adapter provided)
*Exhaust connection adapter: NW 25 KF adapter provided
*Gas ballast: 1 ⁄ 4 ” Female NPT (shipped with port plug installed)
*Operating voltages: 200-240V, 1Ø, 50/60Hz
*Maximum line current: 200V; 6 A 240V; 5 A
*Weight – pump only: 32 kg (71 lbs)
*Compliance: CE, CSA/CUS
-
پمپ خلاء خشک | پمپ خلا MSD Dry Pump
Agilent Chromatograph MSD Dry Pump
- Integral Leak Rate: 1 mbar l/sec
- Number of Cylinders: 4
- Nominal Volume Flow Rate: 3.0 m3/h (50 Hz)
- Permissible Exhaust Pressure: 1100 mbar
- Remanufactured Agilent G3170-80028 MVP 055-3 Diaphragm Dry Vacuum Pump, 100-120 V, 200-240 V 50/60 Hz, PKT01301 gas chromatography / mass spectrometry foreline pump for use with series 5975
-
قیمت پمپ خلا | پمپ خلا آزمایشگاهی Agilent
MS40+ Mono Stage Rotary Vane Pump:
*MS40+ RVP, 25KF Inlet Flange, with I/O and RS232/485 Interface, without Oil Level Sensor
*Free air displacement: 828 l/min (29.2 cfm; 49.7 m 3 /h)
*Pumping Speed: (at 5 mbar inlet pressure) 40 m 3 /h
*Ultimate Total Pressure: 5×10 -2 mbar
*Oil Capacity min/max: 1 l
*Motor Rating 3ph: 0.75 kW
*Noise Level with gas ballast closed: ≤ 62 dB(A)
*Oil Temperature: 60 °C
*Pump operating: 140 °F
*IP Value: 20
*Installation category: II
*Pollution degree: 2
*Operating Temperature Range: 12 – 40 °C
*Nominal rotation speed: 1450 rpm
*Weight: 33 Kg
*Inlet Flange 949-9225: DN 25KF
*Inlet Flange 949-9240 / 949-9941: DN 40KF
*Exhaust Flange: DN 25KF
*Dimensions: 418 x 297 x 228 mm
*Nominal Input Voltage: 200-240 V
*Input frequency : 50 / 60 Hz
*Max input power: 1200 VA
*Internal Main Fuse: (TT type) 12.5 A
-
فروش پمپ وکیوم / خرید پمپ وکیوم / قیمت پمپ
DS 102 Varian :
*Dual Stage Rotary Vane Vacuum Pump
*Applications:
Analytical Instruments
Mass Spectrometry
Electron Microscopes
Leak Detection
Industrial Vacuum Processes
High Energy Physics
Reasearch Laboratories
*Free air displacement: 95 l/min
*Pumping speed: 5 m3/h
*Ultimate partial pressure: 10-4 mbar
*Ultimate total pressure: 2 x 10-3 mbar
*Ultimate total pressure with gas ballast: 2 x 10-2 mbar
*Water vapor tolerance: 15 mbar
*Water vapor capacity: 60 g/h
*Oil capacity min/max: 0.2/0.5 l
*Motor rating 1ph: 0.45 kW
*Nominal rotation speed: 1500 rpm
*Weight: 22Kg
*Inlet flange: 25KF DN
*Exhaust flange: 25KF DN
-
پمپ خلاء | پمپ خلا آزمایشگاهی | قیمت پمپ خلا
DS 602 Varian :
*Dual Stage Rotary Vane Vacuum Pump
*Applications:
Analytical Instruments
Mass Spectrometry
Electron Microscopes
Leak Detection
Industrial Vacuum Processes
High Energy Physics
Reasearch Laboratories
*Free air displacement: 504 l/min
*Pumping speed: 25 m3/h
*Ultimate partial pressure: 10-4 mbar
*Ultimate total pressure: 2 x 10-3 mbar
*Ultimate total pressure with gas ballast: 1 x 10-2 mbar
*Water vapor tolerance: 30 mbar
*Water vapor capacity: 550 g/h
*Oil capacity min/max: 0.5/1 l
*Motor rating 1ph: 0.75 kW
*Nominal rotation speed: 1500 rpm
*Weight: 35Kg
*Inlet flange: 25KF DN
*Exhaust flange: 25KF DN
-
اسپکتروفلوریمتر | خرید اسپکتروفلوریمتر | فروش اسپکتروفلوریمتر
Cary Eclipse Fluorescence Spectrophotometer
*Modes for : fluorescence,phosphorescence and
bio-/chemi-luminescence
*Dimensions(WxDxH) : 60 x 64 x 27 cm (23 x 25 x 10 inches)
*QuantityEa Sensitivity: > 500:1 RMS, 500 nm excitation, excitation and emission slits 10 nm / > 750:1 RMS, 350 nm excitation, excitation and emission slits 10 nm
*Wavelength(s): 190 – 1100 nm
*Temperature Range: 10 – 35°C
*Optical SystemCerny-Turner 0.125 m Monochromators
*Light Source: Xenon Flash Lamp
-
نشر اتمی پلاسمای مایکروویو
MP4210-AES
*Wavelength Range: 213.857 to 614.171 nm (depending on element)
*Detection Limit: 1 to 6 ug/L
*Signal stability: < 2% RSD over 4 hours without internal standardization
or any form of drift correction.
*Resolution: < 0.050 nm (measured as full width at half maximum)
*Detection limits: 3 sigma detection limits (Μg/L) using a 10 second
integration time with dewar nitrogen.
*Applications: Geochemistry, Food Testing and Agriculture, Energy and Fuels, Environmental
*Dimensions: 66 x 66 x 90 cm
*Weight: 73 kg