تیپ استیشن Agilent TapeStation 2200
Application: RNA / DNA / Protein Analysis
Capacity: 16 Tube Strip Vials / 96 Well Plates
Power consumption: 40 W
Dimensions: 40 x 31 x 31 cm
Weight: 12.5 kg
Optimal operating temperature: 23 °C
Ambient operating temperature: 10 – 37 °C
-
ریل تایم پی سی آر QIAGEN Rotor-Gene Q real-time PCR
Outstanding thermal and optical performance due to rotary format
An unmatched optical range spanning UV to infrared wavelengths
State-of-the art analyses supported by user-friendly software
Low maintenance and maximum convenience due to robust design
High performance in multiple applications with QIAGEN assays -
تیشو پروسسور مدل MTP کمپانی SLEE
Easy loading and full process control by rotating table principle
Integrated UPS system protects your samples
Up to 240 cassettes per run
Intuitive control panel
Delayed start function
System Status Monitor
Password protected software -
دستگاه تیتراسیون کارل فیشر Aquamax KF
Measuring range: 1µg – 10 mg water
Moisture range: 1 ppm – 100 % water
Max. sensitivity: 0 . 1µg
Max. titration speed: 2 mg per minute
Max. electrolysis current: 400 ma
-
اسپکتروفتومتر PERKIN ELMER RX I (RX-1) FT-IR
FT-IR Spectrometer
Perkin Elmer
Spectrum RX1
Range: 450-4000 cm-1;
Resolution: 1 cm-1
IR Spectra of liquid/solid samples. -
اتوسمپلر آجیلنت SPS4
*high-capacity (up to 360 samples or 768 microtiter wells)
*Dimensions: Width 600 mm Depth 320 mm Depth 363 mm including peristaltic pump Height 510 mm
*Weight: 15 kg
*Rinse port flow rate: Programmable, up to 50 mL/min depending on pump tube diameter
*Communication: USB 2.0 (full speed) virtual com port with plug-and-play capability.
*AUX interface: RS485 for future upgradability to external device control.
-
اتوسمپلر آجیلنت ۷۶۹۳A
Syringe size: 1 to 500 µL
Solvent saving: 10%, 20%, 30%, 40%, 80% of syringe size (µL)
Injection volume: 1 – 50% of syringe size (µL)
Sample pumps: 0 – 15
Viscosity delay: 0 – 7 seconds
-
اتوسمپلر ASX 520
ASX 520
Operating Temperature: 10° to 30°C
Relative Humidity: 0% to 95%
Altitude: 0 to 10000 Ft
Dimensions (H x W x D): 61 with sample probe x 48.2 x 48.2 cmWeight: 10.5 kg
Trays: 4 racks capacity
Communication interface: USB (virtual COM port); 2 Serial (RS-232) ports
Power supply: 100-240 VAC, 47-63 Hz, 1.9A
-
خرید کوره جذب اتمی / فروش کوره اجیلنت
GTA120 agilent
GTA 120 Zeeman:
*Extremely fast atomization
*Best signal-to-noise
*Reduced running costs
*Programmable Sample Dispenser (PSD)
*Simple method development
*Longer unattended runs
*Weight:
Net: 48 kg Shipping: 83 kg
*Dimensions (W x D x H):
Control unit 240 x 570 x 580 mm
Zeeman 220 x 290 x 340 mm
Packed 950 x 760 x 900 mm [includes PSD]
*Gas supplies:
Recommended pressure: 140 kPa (20 psi)
Maximum pressure: 350 kPa (50 psi)
Normal flow rate approx: 0–3.5 L/min
*Water Supply
Maximum temperature 40 °C (104 °F)
Recommended temp. range: 18–25 °C (64–70 °F)
Minimum flow rate required: 1.5 L/min at 180 kPa (27 psi)
Typical flow rate at recommended pressure range: 1.5–2.0 L/min
Maximum pressure to the regulator: 700 kPa (100 psi)
-
خرید Mini Thermal Disorber/ فروش Mini Thermal Disorber
380,000,000 ریال7667A Mini Thermal Desorber
*Operating temp range: 5 to 45 °C
*Operating humidity range: 5 to 95% (noncondensing )
*Carrier gas: 50 -85 Psi
*Conditioning flow: 50 ml/min
*Conditioning time: 20 min
*Conditioning temperature: 320 °C
*Transfer line temperature: 150 °C
*Valve box temperature: 150 °C
*Type of carrier gas: Nitrogen/Helium
-
خرید Infinity II LC 1220 / فروش Infinity II LC 1220
Infinity II LC 1220
Weight 30 kg Dimensions 640 × 370 × 420 mm Permitted Ambient Temperature 4 ˚C – 55 ˚C Permitted Ambient Humidity < 95 % r.h. at 40 ˚C Hydraulic System Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and passive inlet valve Gradient Formation Low pressure dual mixing/gradient capability using proprietary high-speed proportioning valve, Pump delay volume 600 – 900 μl, system delay volume 800 – 1100 μl, dependent on back pressure Pressure Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 mL/min (all versions), Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 mL/min, Operating range 0 – 60 MPa (0 – 600 bar, 0 – 8700 psi) up to 5 mL/min Power Requirement 240 VA Flow Rate 0.2 – 10.0 mL/min Flow Precision <0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow Accuracy ± 1% or 10 μl/min whatever is greater Settable flow range 0.001 – 10 mL/min, in 0.001 mL/ min increments pH Range 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Injection Range 0.1 – 100 μL in 0.1 μL increments, Up to 1500 μL with multiple draw (hardware modification required) Replicate Injections 1 – 99 from one vial Sample Tray Capacity 100 × 2-mL vials in 1 tray, 15 × 6-mL vials in ½ tray (Agilent vials only), 40 × 2-mL vials in ½ tray Minimum Sample Volume 1 μL from 5 μL sample in 100 μL microvial, or 1 μL from 10 μL sample in 300 μL microvial Sample Viscosity Range 0.2 – 50 cp Injection Cycle Time Typically 50 s depending on draw speed and injection volume Column Oven Capacity (Internal volume: 6 μL), One 25-cm column Oven Temperature Range 5 °C above ambient to 80 °C Detector [Diode Array Detector (type: 1024-element diode array, Light source: Deuterium and tungsten, Sampling rate: 80 Hz, Wavelength range: 190-950 nm,, Slit width: 1,2,4,8,16 nm, Diode width: <1 nm)], [Variable Wavelength Detector (Detection type: Double-beam photometer, Light source: Deuterium lamp, Wavelength range: 190 – 600 nm, Band width: 6.5 nm typical)] Software ChemStation, EZChrom, Instrument Utility, LabAdvisor