agilent
-
خرید Infinity II LC 1220 / فروش Infinity II LC 1220
Infinity II LC 1220
Weight 30 kg Dimensions 640 × 370 × 420 mm Permitted Ambient Temperature 4 ˚C – 55 ˚C Permitted Ambient Humidity < 95 % r.h. at 40 ˚C Hydraulic System Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and passive inlet valve Gradient Formation Low pressure dual mixing/gradient capability using proprietary high-speed proportioning valve, Pump delay volume 600 – 900 μl, system delay volume 800 – 1100 μl, dependent on back pressure Pressure Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 mL/min (all versions), Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 mL/min, Operating range 0 – 60 MPa (0 – 600 bar, 0 – 8700 psi) up to 5 mL/min Power Requirement 240 VA Flow Rate 0.2 – 10.0 mL/min Flow Precision <0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow Accuracy ± 1% or 10 μl/min whatever is greater Settable flow range 0.001 – 10 mL/min, in 0.001 mL/ min increments pH Range 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Injection Range 0.1 – 100 μL in 0.1 μL increments, Up to 1500 μL with multiple draw (hardware modification required) Replicate Injections 1 – 99 from one vial Sample Tray Capacity 100 × 2-mL vials in 1 tray, 15 × 6-mL vials in ½ tray (Agilent vials only), 40 × 2-mL vials in ½ tray Minimum Sample Volume 1 μL from 5 μL sample in 100 μL microvial, or 1 μL from 10 μL sample in 300 μL microvial Sample Viscosity Range 0.2 – 50 cp Injection Cycle Time Typically 50 s depending on draw speed and injection volume Column Oven Capacity (Internal volume: 6 μL), One 25-cm column Oven Temperature Range 5 °C above ambient to 80 °C Detector [Diode Array Detector (type: 1024-element diode array, Light source: Deuterium and tungsten, Sampling rate: 80 Hz, Wavelength range: 190-950 nm,, Slit width: 1,2,4,8,16 nm, Diode width: <1 nm)], [Variable Wavelength Detector (Detection type: Double-beam photometer, Light source: Deuterium lamp, Wavelength range: 190 – 600 nm, Band width: 6.5 nm typical)] Software ChemStation, EZChrom, Instrument Utility, LabAdvisor -
-
چیلر آزمایشگاهی | خرید چیلر آزمایشگاهی | فروش چیلر آزمایشگاهی
375,000,000 ریالChiller G3292A Agilent
– Electrical Requirements: 220-240VAC, 50Hz, 1450 VA
– Voltage ±10%, Frequency ±1Hz
– Cooling capacity:
– Axial system: 1 kW
– Radial system: 200W
– Flow rate: 1.1 L/min (0.3 gpm) minimum
– Recommended inlet temperature: 20°C (68°F)
Maximum for Agilent 720 Series ICP-OES: 30°C (86°F)
Maximum for Agilent 710 Series ICP-OES: 4°C (113°F)
– Minimum inlet pressure: 55 kPa (8.0 psi)
– Maximum inlet pressure: 310 kPa (45 psi)
– Weight: 181 lb. (82 kg)
– Dimensions: 368 x 575 x 702 mm
ا Working Temperature
Range °C -10° to 40°
-
خرید Mini Thermal Disorber/ فروش Mini Thermal Disorber
380,000,000 ریال7667A Mini Thermal Desorber
*Operating temp range: 5 to 45 °C
*Operating humidity range: 5 to 95% (noncondensing )
*Carrier gas: 50 -85 Psi
*Conditioning flow: 50 ml/min
*Conditioning time: 20 min
*Conditioning temperature: 320 °C
*Transfer line temperature: 150 °C
*Valve box temperature: 150 °C
*Type of carrier gas: Nitrogen/Helium
-
چیلر آزمایشگاهی | خرید چیلر آزمایشگاهی | فروش چیلر آزمایشگاهی
428,000,000 ریالG1879A Agilent
Agilent heat exchanger:
Heat to be dissipated: 1,600W approximately
Flow Rate: > 5L/min
Inlet pressure: 230-400kPa (33-58psi)
Temperature: 15-40 ° C at water inlet of ICP-MS
Conductivity : 50-150µS at the chiller reservoir
Water Filter: <100 microns particle size
Connections:
Hose 1 × 10m long, ID=12mm (7/16inch); Male PT 1/2inch fittings on the
7700 ICP-MS end
Dimensions: 57.2 x 38.0 x 51.4 cm
Weight: 42Kg
-
چیلر آزمایشگاهی | خرید چیلر آزمایشگاهی | فروش چیلر آزمایشگاهی
560,000,000 ریالچیلر آزمایشگاهی | خرید چیلر آزمایشگاهی | فروش چیلر آزمایشگاهی
فروش چیلر های ازمایشگاهی / G8481A
Agilent chiller:
– Electrical Requirements: 220-240VAC, 50Hz, 1450 VA
– Voltage ±10%, Frequency ±1Hz
– Cooling capacity:
– Axial system: 1 kW
– Radial system: 200W
– Flow rate: 1.1 L/min (0.3 gpm) minimum
– Recommended inlet temperature: 20°C (68°F)
Maximum for Agilent 720 Series ICP-OES: 30°C (86°F)
Maximum for Agilent 710 Series ICP-OES: 4°C (113°F)
– Minimum inlet pressure: 55 kPa (8.0 psi)
– Maximum inlet pressure: 310 kPa (45 psi)
– Weight: 181 lb. (82 kg)
– Dimensions: 368 x 575 x 702 mm
ا Working Temperature
Range °C -10° to 40°